5. Known problems and limitations
5.1. Netdata: displaying information in the GCenter V2.5.3.101 WebUI
Revamping and adding new information at the Netdata level renders the graphics and statistics displayed on the GCenter V2.5.3.101 WebUI inoperative.
The data can still be accessed via the Netdata API.
5.2. Modification of the MTU of a VPN interface and tunnel
Changing the MTU of a GCap interface results in the network configuration of all interfaces being re-applied.
This has the effect of losing connectivity between GCap and GCenter (IPsec VPN) for about 4 minutes.
5.3. Restore the backup on GCenter.
When restoring the backup on the GCenter, pairing with the GCaps must be performed again.
5.4. Error during first network configuration
During initial network configuration, an error appears.
There are 4 steps to fully validate the network configuration:
configure the hostname
configure the domain name
configure the ip address
Selection of management/VPN interfaces;
As long as the 4 parameters are not filled in, an error appears when validating the first 3 parameters.
5.5. Error and logout when entering an incorrect value for the date
When configuring the date and time of a GCap, if an incorrect value is entered then an error is displayed and the SSH connection is closed.